Fine Chemical Industry Tops Reagent Chromogenic Substrate CAS 40567-80-4
Product Details
| Customization: | Available |
|---|---|
| CAS No.: | 40567-80-4 |
| Formula: | C12h18nnao3s |
Manufacturer/Factory & Trading Company
360° Virtual Tour
Diamond Member Since 2023
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Patents Awarded
Exhibition Experience
The supplier has import and export rights
The supplier had awarded 2 patents, you can check the Audit Report for more information
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Sign In to see all verified strength labels (17)
Find Similar Products
Basic Info.
- Model NO.
- Tops
- EINECS
- Non
- Classification
- Biochemical Reagents
- Grade
- AR
- Specific Usage
- For Biological Purpose, Pro Analysis
- Content
- Standard
- Usage
- Laboratory Reagents, Analytical Reagents, Diagnostic Reagents
- Source
- Dry Powder
- Habit Appellation
- Fine Chemicals
- Application
- Industry, Scientific Research, Health
- Property
- Biochemical Reagent
- OEM Packing
- Yes
- Purity
- 99%
- Ivd Reagent
- Yes
- Delivery Time
- 5-7days
- CAS Number
- 40567-80-4
- Molecular Formula
- C12h20nnao3s
- Molecular Weight
- 281.35
- Colour
- White Powder
- Storage Conditions
- Protected From Light and Moisture
- Transport Package
- Bottle
- Specification
- 50g/bottle
- Trademark
- Desheng
- Origin
- China
- HS Code
- 2921499090
Product Description
Tops Chromogenic Substrate cas 40567-80-4
Storage condition:0-5ºC, keep away from light and moisture
Transport conditions:Room temperature
Oxidation reaction
Usage:It can be applied to the enzymatic photometric determination of hydroge n peroxide as a water-soluble reagent, widely used in diagnostic tests and biochemical tests
Product Advantages:The product has good crystal form, high purity, high colour sensitivity, good water solubility and stable process, which can ensure the appearance of pure white crystal powder.
The following focuses on giving you an analysis of its advantages in various aspects, so that you can also judge accurately when choosing at a later stage.
I. Absorbance wavelength
The absorbance wavelength of TOPS oxidised products can reach 550NM, which is already far more than other reagents. TOPS is very suitable for biochemical research where highly accurate values are required. Due to the long absorbance wavelength, it is possible to better identify and judge the content of substances in the determination of some substances, which makes it easier to obtain accurate results without affecting the composition of the sample to be measured.
II. Wide range of solution pH
The advantage of the wide pH range of TOPS solutions is that if used in biochemical studies or enzyme photometric assays, the enzyme reaction is not affected to a greater extent. Because enzymes are more sensitive to environmental pH requirements in catalytic reactions, TOPS solutions have a pH range of 5.5-9.5, which is a suitable pH range for enzymes to survive and not easily change.
III.High molar absorbance
TOPS has a high molar absorbance of 3.74×10, which makes it more responsive during the detection process, but care needs to be taken that the detection time is not too long to ensure a rapid response without interruption in timely detection.
IV. High water solubility and purity
As TOPS is more sensitive to surrounding light and humidity, it has the advantage of high water solubility, while the purity is usually based on the manufacturer, such as the TOPS produced by Tesheng is up to 99% pure, suitable for most biochemical experimental projects, and process stability, we can also focus on the purity advantage when choosing. Also note that because of the good water solubility, TOPS needs to be placed in a light-proof and airtight container and kept at a temperature of 0-5 degrees.
Company introduction
As a professional R&D and production manufacturer of chromogenic substrates, Desheng has a complete range of products, such as TOOS, TOPS, ADOS, ADPS, MAOS, etc., which can provide customers with one-stop purchasing service. With 18 years of experience in manufacturing, the quality of our products has been widely recognized by the market, so in recent years we have been expanding abroad and selling our products to countries all over the world. If you are interested in purchasing, please feel free to contact us.
| English Name: | Sodium 3-(N-ethyl-3-methylanilino)propanesulfonate |
| Chinese name: | N-ethyl-N-(3-sulfopropyl)-3-methylaniline sodium salt, monohydrate |
| Abbreviation: | TOPS |
| CAS# | 40567-80-4 |
| Molecular Weight: | 279.33 |
| Molecular Formula: | C12H18NNaO3S |
| Purity: | >99% |
| Solution pH range: | 5.5-9.5 |
| Molar Absorbance Coefficient: | 3.74x104 |
| Absorbance wavelength (unit: nm): | 550 |
Storage condition:0-5ºC, keep away from light and moisture
Transport conditions:Room temperature
TOPS powder
Oxidation reaction
Usage:It can be applied to the enzymatic photometric determination of hydroge n peroxide as a water-soluble reagent, widely used in diagnostic tests and biochemical tests
Product Advantages:The product has good crystal form, high purity, high colour sensitivity, good water solubility and stable process, which can ensure the appearance of pure white crystal powder.
The following focuses on giving you an analysis of its advantages in various aspects, so that you can also judge accurately when choosing at a later stage.
I. Absorbance wavelength
The absorbance wavelength of TOPS oxidised products can reach 550NM, which is already far more than other reagents. TOPS is very suitable for biochemical research where highly accurate values are required. Due to the long absorbance wavelength, it is possible to better identify and judge the content of substances in the determination of some substances, which makes it easier to obtain accurate results without affecting the composition of the sample to be measured.
II. Wide range of solution pH
The advantage of the wide pH range of TOPS solutions is that if used in biochemical studies or enzyme photometric assays, the enzyme reaction is not affected to a greater extent. Because enzymes are more sensitive to environmental pH requirements in catalytic reactions, TOPS solutions have a pH range of 5.5-9.5, which is a suitable pH range for enzymes to survive and not easily change.
III.High molar absorbance
TOPS has a high molar absorbance of 3.74×10, which makes it more responsive during the detection process, but care needs to be taken that the detection time is not too long to ensure a rapid response without interruption in timely detection.
IV. High water solubility and purity
As TOPS is more sensitive to surrounding light and humidity, it has the advantage of high water solubility, while the purity is usually based on the manufacturer, such as the TOPS produced by Tesheng is up to 99% pure, suitable for most biochemical experimental projects, and process stability, we can also focus on the purity advantage when choosing. Also note that because of the good water solubility, TOPS needs to be placed in a light-proof and airtight container and kept at a temperature of 0-5 degrees.
Company introduction
As a professional R&D and production manufacturer of chromogenic substrates, Desheng has a complete range of products, such as TOOS, TOPS, ADOS, ADPS, MAOS, etc., which can provide customers with one-stop purchasing service. With 18 years of experience in manufacturing, the quality of our products has been widely recognized by the market, so in recent years we have been expanding abroad and selling our products to countries all over the world. If you are interested in purchasing, please feel free to contact us.
Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- Chromogenic substrates
- Fine Chemical Industry Tops Reagent Chromogenic Substrate CAS 40567-80-4
Related Categories
Hot Searches
More