High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives

Product Details
Customization: Available
CAS No.: 9045-22-1
Formula: (C14h25no20s3)N.Xli
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (16)
  • High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives
  • High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives
  • High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives
  • High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives
  • High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives
  • High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives
Find Similar Products

Basic Info.

Model NO.
Heparin Lithium
Appearance
Powder
Usage
Blood Collection Tubes Additives
Color
White
OEM Packing
Yes
Safety
Yes
Anticoagulant
Yes
Primitive Trait
White Amorphous Powder
Performance
Odorless, Soluble in Water, Easily Hy
Potency
Greater Than 150iu/Mg
Average Molecular Weight
15000
Valid Period
3 Years
Transport Package
Bottle
Specification
10g/bottle; 50g/bottle
Trademark
Desheng
Origin
China
HS Code
29319090

Product Description

Heparin Lithium Salt Porcine Intestinal Mucosa CAS 9045-22-1
 
Product Name  Lithium heparin
Package Specification  Plastic bottle, 10g/bottle, 20g/bottle, 50g/bottle

[Performance] White amorphous powder, odorless, soluble in water, easy to absorb moisture, average molecular weight of 15,000, stable at room temperature. The potency of lithium heparin of the company is ≥150IU/mg, and the potency of anhydrous litnium heparin is ≥ 160IU/ mg. Other indexes were controlled according to the standard of heparin sodium.
 
High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives
High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives

 
Lithium heparin powder

[Scope of application]
1. This product is applicable to the collection and anti-coagulation of blood samples for clinical biochemical examination and emergency biochemical examination, as well as the collection and anti-coagulation of blood samples for some hemorheology projects.
2. It is recommended to use lithium heparin as anticoagulant in clinical test to determine the ions in blood, because it is the least likely to interfere with the determination of other ions.
3. This product is not a drug and cannot be used as an injection. It is forbidden to inject directly into human body and animals.

[Precautions]
In order to ensure adequate anti-coagulation of blood, the heparin salt must be mixed upside down for 5-8 times as soon as possible after blood collection. Especially when the temperature of blood collection environment is higher than 25ºC, the mixing of blood and lithium heparin must be timely and sufficient, otherwise it is easy to lead to blood coagulation or local coagulation.
Heparin anti-coagulation is not irreversible, so the test should be completed within 6 hours after blood collection in lithium heparin anti-coagulation test tube, otherwise the test results may be wrong.

Heparin may be involved in the metabolism of cell enzymes and ions, so the use of heparin may affect the test results. The dosage of heparin should ensure the full anti-coagulation of the whole and local samples, so as to ensure that most of the plasma indexes can be repeated within 6 hours, especially the sensitive indexes such as ast, alt, TBIL, DBIL and GGT.

Lithium heparin can be used at the same time with the separation gel. Anti-coagulation effect, silicification of tube wall, centrifugation conditions, separation gel quality and so on will affect the blood separation effect. It is suggested that high quality plasma samples can be obtained by using the blood separation gel produced by our company.It is recommended to use γ - ray irradiation at a dose of 8-25kgy. The irradiation dose can be determined by the initial colony number.


Company Introduction
Hubei New Desheng Material Technology Co., Ltd. specializes in the production of blood collection tube additives, chemiluminescent reagents, biological buffers, chromogenic substrates, enzyme preparations, antigen antibodies and other biochemical reagents. Founded in 2005, Desheng has a professional R&D team and advanced production equipment!
High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives
High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives
 
High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives
High Quality Heparin Lithium Salt CAS 9045-22-1 Chemicals Product Anti-Coagulation Additives

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier